Those things about high and low temperature test box handling

The high and low temperature test box itself is equipped with a universal caster. If the equipment is placed directly on the first floor, use a manual hydraulic forklift to directly remove it and then push it to the laboratory. If the test box is placed on the upper floor, it should focus on whether there is an elevator Width and height and whether the aisles, corridors, and doors that need to pass to enter the test room can be smoothly entered. If there is no elevator to be manually moved, special care should be taken.

If the high and low temperature test chamber must be manually moved upstairs due to site problems, the following points need special attention:

1. The standard size of the high and low temperature test chamber is divided into five types: 100, 225, 504, 800, and 010, and the low temperature range is 0, -20, -40, -60, -70, -80. What needs to be stated here is when When the size of the test box exceeds 504 liters and the temperature range exceeds -60 degrees, we do not recommend the use of transportation, because the weight and volume are too large, it may cause damage to personnel and machines and major safety hazards, you can use a crane, replace the place or replace size.

2. If the test box is within the range of transportation, the manufacturer recommends to find a professional moving company and a manufacturer's technician to provide on-site guidance, complete tools, sufficient space at the entrance of the corridor and the average strength distribution of the transportation personnel. Guided to move correctly.

High and low temperature-low temperature.jpg

3. Because the high and low temperature test chamber is cooled by compressor refrigerant, it must not be tilted during the transportation process (such as the tilt angle cannot exceed 15 degrees in special cases). It should be moved vertically and parallelly like the air conditioner, to avoid the failure of refrigeration due to Freon leakage.

4. The outer bladder of the test chamber is treated with anti-static plastic spray on the steel plate, and the related parts are made of stainless steel. Therefore, avoid impact, bumps, and scratches during transportation, so as not to affect the appearance of the machine. The entire test chamber shell needs to be re-sprayed, which is very expensive.) If it is filled separately, it will still affect the appearance.

5. The hinge of the gate needs to be taken care of to avoid the door sag or unstable center of gravity caused by loosening.

6. If it is a test chamber with humidity, please prevent the cup from breaking.

Handling is a measure with significant safety hazards. It is not recommended to adopt it in special circumstances. When selecting the volume, temperature range, and test function of the test box, the user should not only consider the function of the sample to be realized, but also should Consider whether forklifts, elevators, aisles, corridors, doors, windows and other facilities can allow high and low temperature test chambers to be put into the designated test area without obstruction. Those things about high and low temperature test box handling