This reagent is for research purpose only: This kit is used to determine the activity of ascorbic peroxidase (APX) in plant tissues, cells and other related samples. Shanghai Yanjin biological high-quality ELISA kit supplier, excellent quality, perfect after-sales. For more information, welcome to provide free testing services.

Experimental principle:

This kit uses the double antibody sandwich method to determine the level of plant ascorbate peroxidase (APX) in the specimen. Microporous plates were coated with purified plant ascorbate peroxidase (APX) antibody to prepare solid-phase antibodies. Plant ascorbate peroxidase (APX) was added to the microwells coated with mAb in turn, followed by HRP-labeled The ascorbate peroxidase (APX) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the ascorbate peroxidase (APX) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of plant ascorbate peroxidase (APX) in the sample was calculated by a standard curve.

Kit composition:

Kit composition

48 hole configuration

96-well configuration

save

Instructions

1 serving

1 serving

Sealing film

2 pieces (48)

2 pieces (96)

sealed bag

1

1

Enzyme coated plate

1 × 48

1 × 96

Store at 2-8 ℃

Standard product: 225IU / ml

0.5ml × 1 bottle

0.5ml × 1 bottle

Store at 2-8 ℃

Standard dilution

1.5ml × 1 bottle

1.5ml × 1 bottle

Store at 2-8 ℃

Enzyme reagent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Sample diluent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer A liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer B liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Stop solution

3ml × 1 bottle

6ml × 1 bottle

Store at 2-8 ℃

Concentrated washing liquid

(20ml × 20 times) × 1 bottle

(20ml × 30 times) × 1 bottle

Store at 2-8 ℃

Specimen requirements:

1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided

2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.

Steps:

1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of the standard products in the first and second wells, and then add the standard products in the first and second wells. 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentration is 150 IU / ml, 100 IU / ml, 50 IU / ml, 25 IU / ml, 12.5IU / ml)

2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.

3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.

4. Mixing solution: Dilute 30 times (20 times of 48T) concentrated washing liquid with distilled water 30 times (20 times of 48T) and then use.

5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry.

6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.

7. Incubation: The operation is the same as 3.

8. Washing: The operation is the same as 5.

9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.

10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).

11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Precautions:

1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.

2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.

3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.

4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).

5. The sealing film is limited to one-time use to avoid cross-contamination.

6. Please keep the substrate away from light.

7. Strictly follow the instructions, and the test results must be determined by the microplate reader.

8. All samples, washing liquids and various wastes should be treated as infectious agents.

9. The components of different batches of this reagent shall not be mixed.

10. If there is any difference with the English manual, the English manual shall prevail.

Calculation:

Taking the concentration of the standard as the abscissa and the OD value as the ordinate,

Draw a standard curve on coordinate paper, according to the OD of the sample

The value is determined by the standard curve; then multiplied by the dilution

Multiple; or calculate the standard using the concentration and OD value of the standard

The linear regression equation of the quasi-curve, the OD value of the sample

Substitute into the equation, calculate the sample concentration, and multiply by the dilution

The multiple is the actual concentration of the sample.

Kit performance:

1. The correlation coefficient R between the linear regression of the sample and the expected concentration is above 0.92.

2. The batch and approval should be less than 9% and 15% respectively

Storage conditions and validity period:

1. Store the kit: 2-8 ℃.

2. Validity: 6 months

Shanghai Yanjin Biological Technology Co., Ltd. specializes in selling ELISA kits of various brands and price levels. Serving universities and immunology research units. Quality assurance and perfect after-sales service. And can be free to detect, better service for you.

The Harmony Vinyl Mattress Protector helps you to get the good night's rest that you need. With just one unprotected fluid accident,a mattress can be left with a permanent stain or odor. Our mattress protectors can provide protection against dust mites, fluids, urine, perspiration, allergens and bacteria. This has made them especially helpful for those with kids, pets, allergies, asthma or incontinence. The Harmony mattress protector offers a more peaceful and sterile sleeping environment for you and your family.